FeelTech FY6900 20M-60M Function Signal Generator High Precision Digital DDS Dual-channel Function Signal/Arbitrary Waveform Generator

  • $159.00
    Unit price per 

Only 27 left!
Item No. LM99M76A-4 Weight: 1.2 kg
Estimated: Standard 7-15 working days.
                      Expedited Shipping 3-6 working days.

 FeelTech FY6900 20M-60M Function Signal Generator High Precision Digital DDS Dual-channel Function Signal/Arbitrary Waveform Generator

 

Offer 20M, 30M, 50M, 60M four models for choice!! Please select the correct model you want!

 

Please Leave message for Voltage and AC Power adapter Type:
110V US
230V UK
220V EU
240V AU

 

Package List:
1 * DDS Signal Generator
1 * Power Cable
1 * USB Data Cable
1 * BNC-BNC Cable
2 * BNC-Clip Cable

 

frequency characteristic

Product Model

FY6900-20M

FY6900-30M

FY6900-50M

FY6900-60M

Frequency range of Sine wave

0~20MHz

0~30MHz

0~50MHz

0~60MHz

Frequency range of square wave

0~15MHz

0~20MHz

0~25MHz

0~25MHz

Frequency range of other waves

0~10MHz

0~10MHz

0~10MHz

0~10MHz

Minimum adjustable width of pulse wave

20ns

Minimum Frequency Resolution

1μHz

Waveform Length

8192 points (8K points) *14Bits

Waveform sampling rate

250MSa/s

Vertical Resolution of Waveform

14 Bits

Amplitude range (peak to peak)

frequency≤5MHz

5MHz< frequency≤10MHz

10MHz< frequency≤20MHz

frequency >20MHz

1mVpp~24Vpp

1mVpp~20Vpp

1mVpp~10Vpp

1mVpp~5Vpp

Amplitude resolution

1mV

Output impedance

50Ω±10%(typical)

Bias Adjustment Range

frequency≤20MHz:±12V; frequency >20MHz: ±2.5V

Minimum Bias Resolution

1mV

Phase adjustment range

0~359.99°

Minimum phase resolution

0.01°

display

2.42.4 inches TFT color liquid crystal display

Interface

115200 bps

Power Supply

AC100V~240V

environment condition

temperature:0~40℃  humidity:﹤80%

 

·Frequently Asked Questions 

Fault phenomenon

Solution

Turn the power button to the "-" side, the signal generator screen is still not lit, there is no display, the channel indicator is not lit

1)  Check if the power connector is connected.

2)  Check that the power button is in place.

3)  After completing the above checks, restart the instrument.

4)  If you still cannot use the product properly, please contact us.

Signal generator CH2 is locked

1)  Check that the signal generator is operating in sync. Press the SYSTEM button -> SYNC Enter the sync settings interface to cancel all sync parameters.

2)  The power to restart the signal generator can also be unlocked.

Correct setting but no waveform output

1)  Check that the BNC cable is securely connected to the corresponding [CH1] or [CH2] channel output port.

2)  Check the BNC cable for internal damage.

3)  Check that the BNC cable is tightly connected to the test instrument.

4) Check if the upper side indicator of the [CH1] or [CH2] button is lit. If it is not lit, press the corresponding button to make its indicator light.

5)  If you still cannot use the product properly, please contact us.